Search found 3 matches

by geomariolis
Tue Jan 30, 2018 6:57 am
Forum: Scripting
Topic: datalogger change name of curve while logging
Replies: 1
Views: 5485

datalogger change name of curve while logging

hi all, i am using a datalogger and one analog value is being logged. my issue is that while the analog value is always the same, i am changing digitally the sampling point of it. so i would like to be able to see it in the logger. for example i am logging a gas value from tanks. i would like to see...
by geomariolis
Fri Sep 04, 2015 7:21 am
Forum: Controller Communication
Topic: ixt4a serial comm with dot matrix epson lx-300+
Replies: 1
Views: 17348

Re: ixt4a serial comm with dot matrix epson lx-300+

I managed to solve this. The problem was the pin out connection. With epson printer lx350 the pin out must be : DB9 -- DB25 2 2 3 3 5 7 7 20 Printer needs nothing more to be adjusted (factory default adjustments) and in ix developer needs only new line character:CR/LF to be checked. It will work jus...
by geomariolis
Wed Aug 26, 2015 4:00 pm
Forum: Controller Communication
Topic: ixt4a serial comm with dot matrix epson lx-300+
Replies: 1
Views: 17348

ixt4a serial comm with dot matrix epson lx-300+

hi everyone, I'm trying to connect m hmi with the printer without result. I have set the printer in ibm2390+ and port baud rate etc are same as per my port in ix developer. My pinout is the one from rs232 db9 to db25 (i attached the gif) ModemStraightDB9DB25.gif . I have set the character to pc850(m...