At first localize the problem.
What goes wrong, recording data into database table, reading data from the database or recording into into external drive?
If You reduce period of data logging from 1 to 60 sec what happens?
Do You use the original database or created Your own?
Search found 175 matches
- Mon Feb 18, 2019 10:13 am
- Forum: Dynamics
- Topic: Data logger and scheduler
- Replies: 6
- Views: 17528
- Tue Jan 29, 2019 10:39 am
- Forum: Dynamics
- Topic: Data logger and scheduler
- Replies: 6
- Views: 17528
Re: Data logger and scheduler
Check the "Max Number of Logged Rows" in the Data Logger's property.
If number of record made is bigger, the oldest record will be deleted and replaced with the current data.
The default value is 500. If bigger value inserted, an appropriate warning appeared after compilation.
regards, Waldemar
If number of record made is bigger, the oldest record will be deleted and replaced with the current data.
The default value is 500. If bigger value inserted, an appropriate warning appeared after compilation.
regards, Waldemar
- Wed Nov 21, 2018 6:44 am
- Forum: Application Development
- Topic: Adding a new table in the general Database.db using script
- Replies: 1
- Views: 13233
Re: Adding a new table in the general Database.db using scri
Probably, yes. I will google it.
You can add a table to the Database.db with Data Logger.
And You can add an external SQLite database to USB or SD card.
The database errors are not being noticed by iX Developer. Use: try, catch (SQLiteException ).
You can add a table to the Database.db with Data Logger.
And You can add an external SQLite database to USB or SD card.
The database errors are not being noticed by iX Developer. Use: try, catch (SQLiteException ).
- Wed Nov 07, 2018 9:23 am
- Forum: Application Development
- Topic: Alias trend script + Alarm indicator
- Replies: 1
- Views: 5848
Re: Alias trend script + Alarm indicator
It looks like , You want to show on TrendViewer three curves for several signals to choose by operator. I did similar task differently. 1. In “Edit curves” set Curve1 (tag: Curve1Value), Curve2 (tag: Curve2Value) and Curve3 (tag: Curve3Value) with different colours assigned. 2. In “Trend Dynamics” s...
- Wed Oct 17, 2018 8:55 am
- Forum: Application Development
- Topic: Debug Tools
- Replies: 3
- Views: 7916
Re: Debug Tools
Thank You Russ C. for the answer.
I read the reference manual. Not much information is there about debugging. I have Visual Studio 2013 installed. An extra manual (probably, from a third party) would be helpful to learn this option.
Regards, Waldemar
I read the reference manual. Not much information is there about debugging. I have Visual Studio 2013 installed. An extra manual (probably, from a third party) would be helpful to learn this option.
Regards, Waldemar
- Fri Sep 28, 2018 4:28 am
- Forum: Application Development
- Topic: Debug Tools
- Replies: 3
- Views: 7916
Debug Tools
Dear colleagues,
Who used Debug tool in iX-Developer, a nice picture of a ladybird in the "Project" page next to "Simulate" button?
How can it be used? Is it effective and useful? Where to find a proper manual?
Who used Debug tool in iX-Developer, a nice picture of a ladybird in the "Project" page next to "Simulate" button?
How can it be used? Is it effective and useful? Where to find a proper manual?
- Wed Jul 18, 2018 2:40 am
- Forum: Database
- Topic: How to insert values to the "Time" column of Data Logger
- Replies: 1
- Views: 9909
Re: How to insert values to the "Time" column of Data Logger
I found solution. After backing up the internal database to USB memory, it was opened with SQLite Expert and the field "Time" type was changed from datetime to nvarchar.
But, how to insert data to fields with SQL type "datetime" is not yet clear.
But, how to insert data to fields with SQL type "datetime" is not yet clear.
- Thu Jul 05, 2018 4:03 am
- Forum: Database
- Topic: How to insert values to the "Time" column of Data Logger
- Replies: 1
- Views: 9909
How to insert values to the "Time" column of Data Logger
My task is to move a Data Logger from internal HMI memory (X2Pro) to USB or SD. I made backup of existing database on USB and wrote a script to make records. It works, but there is a problem with the field "Time". It has format DateTime.
How to insert a value into this column?
How to insert a value into this column?
- Wed Jun 20, 2018 1:33 am
- Forum: Application Development
- Topic: How to limit the number of characters in a texbox
- Replies: 3
- Views: 7404
Re: How to limit the number of characters in a texbox
Hi, use script.
Globals.Tags.MyTag_rounded.Value =Math.Round((double)Globals.Tags.MyTag.Value,1);//rounds value to 1 decimal
Globals.Tags.MyTag_rounded.Value =Math.Round((double)Globals.Tags.MyTag.Value,1);//rounds value to 1 decimal
- Wed Nov 15, 2017 4:52 am
- Forum: Scripting
- Topic: Getting IP address from system
- Replies: 14
- Views: 38160
Re: Getting IP address from system
Thank You Adam for the link, it is very interesting information. Original task was to check, if the HMI configured as OPC server or client. But, it is not clear, how to check by script, if a controller (OPC client) active or not. Anyway, the problem is solved, because we know now what IP address is ...