Search found 92 matches

by Edmund
Thu Apr 24, 2014 10:37 am
Forum: Application Development
Topic: Problems using DataGrid with T4A
Replies: 6
Views: 9692

Re: Problems using DataGrid with T4A

Hello Edmond. I tryed to modify the XAML file following the example given by you on post http://beijerinc.com/support/ix/forum/viewtopic.php?f=6&t=1573&p=3736&hilit=listview&sid=7c69b3af2d2c35de9ecbe0fa4d6d66d2#p3736 but i can´t get it to work. Always get a XAML error message and I can´t find more ...
by Edmund
Wed Apr 23, 2014 7:06 am
Forum: Application Development
Topic: Problems using DataGrid with T4A
Replies: 6
Views: 9692

Re: Problems using DataGrid with T4A

Try use a Listview instead (it works in runtime).

Set the columns and bindings in the Xaml and load the data into it via ItemsSource.
by Edmund
Fri Apr 18, 2014 8:01 am
Forum: Scripting
Topic: Seting scheduler time
Replies: 8
Views: 19338

Re: Seting scheduler time

Hi! There is no good way of doing this, it´s possible to update a "jobs" interval and startdate in runtime via script but once you restart the project it´s back to the settings made in iX Developer before compile. Beijer has a time channel plugin (dll) available for BIG (Beijer Integrator Group) her...
by Edmund
Fri Apr 18, 2014 12:42 am
Forum: Application Development
Topic: Alarm Indicator
Replies: 4
Views: 8097

Re: Alarm Indicator

Hi! Uncheck the three checkboxes in the Alarm Server settings ("Show Alarm Indicator"), then it will not popup any more. Well if your project target is a TxA or TxB panel it will be using .Net CE (Compact Framework) since it runs on Windows CE. That´s why you have the CE Adapter instead... What are ...
by Edmund
Thu Apr 17, 2014 11:25 am
Forum: Application Development
Topic: Alarm Indicator
Replies: 4
Views: 8097

Re: Alarm Indicator

Create a internal tag (let´s say ActiveAlarm : Bool) and set it when a Alarm goes Active and reset it when you acknowledge the alarms.

And use the tag to show/hide your own alarm inidcator.
by Edmund
Wed Apr 09, 2014 12:14 pm
Forum: Controller Communication
Topic: iX Run to Siemens Simulator
Replies: 2
Views: 8164

Re: iX Run to Siemens Simulator

They wont help you with that (PLCSim was not designed to communicate with anything else that S7 Manager).

But there is a workaround.

http://nettoplcsim.sourceforge.net/
by Edmund
Tue Apr 08, 2014 7:53 am
Forum: Scripting
Topic: How to close screen with script?
Replies: 9
Views: 15833

Re: How to close screen with script?

It´s probably the second one that fires of the event.

Could you copy and paste the code here?

Best Regards
by Edmund
Tue Apr 08, 2014 12:04 am
Forum: Hardware
Topic: CPU running at 90% just to display screen?
Replies: 1
Views: 8018

Re: CPU running at 90% just to display screen?

You have probably chosen a hardware that is to week for your application.

Try use the T7B instead.

Here is also a pdf with some guidelines for optimizing a iX application.

http://ftc.beijer.se/files/C125728B003A ... 00324a.pdf
by Edmund
Mon Apr 07, 2014 9:28 am
Forum: Scripting
Topic: How to close screen with script?
Replies: 9
Views: 15833

Re: How to close screen with script?

From where do you call your ".Show();" code?

Br.
by Edmund
Wed Apr 02, 2014 9:47 am
Forum: Scripting
Topic: How to close screen with script?
Replies: 9
Views: 15833

Re: How to close screen with script?

Globals.MyScreen.Close();

Br.