Re: AB Micro 850 Ethernet communication with E1071

Hi,
For future reference using iX drivers for the Micro 820/850, use the Allen-Bradley Ethernet/IP driver, and select NO for enable rack position addressing.
You can only access the Global Variable tags, but not the __SYSVA tags.
by cfhollis
Tue Aug 27, 2013 2:28 pm
Forum: Controller Communication
Topic: Bosch Rexroth Ethernet
Replies: 5
Views: 15673

Re: Bosch Rexroth Ethernet

I just wanted to toss this in - I successfully connected to a Rexroth PPC-R running Indralogic 1.8 (and Synax 13, but I don't think that's relevant) via Ethernet. The necessary settings in iX are to use a CoDeSys ARTI controller, port 1200, V2 TCP/IP Level 2 Route, Motorola Byte Order, ELAU Controll...
by cfhollis
Fri Mar 22, 2013 7:02 am
Forum: Hardware
Topic: TREQ-VM
Replies: 1
Views: 7982

TREQ-VM

I'm wondering if I can use iX to program a TREQ-VM.
It looks like it has nearly the same specs as a QTERM-A7.