Search found 13 matches
- Mon Jul 23, 2018 8:33 am
- Forum: Tags
- Topic: How to force all tags to be Lightweight during importing
- Replies: 1
- Views: 9020
How to force all tags to be Lightweight during importing
Hi everybody, i am trying to update my old project (iX V2.0) to new version (iX V2.40) and to port it to newer display X2Pro10. In the old project I am using tags as GlobalDataItems in scripts. Now during importing a new list of tags, they are generated as Lightweighttags mostly. I think i could cha...
- Wed Sep 10, 2014 9:07 am
- Forum: Controller Communication
- Topic: FreeCAN driver
- Replies: 1
- Views: 7893
FreeCAN driver
Hello to all,
please tell me where can I find the newest FreeCAN driver. Thanks in advance.
please tell me where can I find the newest FreeCAN driver. Thanks in advance.
- Tue Jan 14, 2014 8:15 am
- Forum: Controller Communication
- Topic: T10A with FreeCAN: Comm Err Station 0
- Replies: 1
- Views: 9374
T10A with FreeCAN: Comm Err Station 0
Hy for everybody!
Sometimes, may be one time in day or in a two days, we have this error. By this time it is quite difficult to say when and after which kind of changes in project it has begun. Has anybody any hints how could i find and fix this problem.
Thanks.
Sometimes, may be one time in day or in a two days, we have this error. By this time it is quite difficult to say when and after which kind of changes in project it has begun. Has anybody any hints how could i find and fix this problem.
Thanks.
- Fri Dec 06, 2013 2:31 am
- Forum: Controller Communication
- Topic: How can i know that CAN is connected?
- Replies: 2
- Views: 9941
How can i know that CAN is connected?
Hello everybody, We are working with T10A panel and communicating with it by means FreeCAN controller. Our client ask to set an additional error "Panel not connected" to see that there is no any connection at all. I see the next decisions: 1. To add new telegram (let say LifeSignal) and consider acc...
- Mon Jun 03, 2013 4:24 am
- Forum: Controller Communication
- Topic: How to send information via J1939?
- Replies: 13
- Views: 43118
Re: How to send information via J1939?
As i understand, we have only int32-type for tags on transmission.
Is it possible to form 8-bytes message at once. In other words: how to prevent sending a message which is not finished?
Is it possible to form 8-bytes message at once. In other words: how to prevent sending a message which is not finished?
- Thu May 30, 2013 12:34 pm
- Forum: Controller Communication
- Topic: How to send information via J1939?
- Replies: 13
- Views: 43118
Re: How to send information via J1939?
Thanks a lot! I'll try to work it out.
- Thu May 30, 2013 2:04 am
- Forum: Controller Communication
- Topic: How to send information via J1939?
- Replies: 13
- Views: 43118
Re: How to send information via J1939?
Hi to all!
Does anybody know how to force the panel to send data only on triggers event? I have made some triggers, then set column "Data exchange" in "Tag's"-table on them, but the controller still sends data also when according data is changing. What could be wrong in my project?
Does anybody know how to force the panel to send data only on triggers event? I have made some triggers, then set column "Data exchange" in "Tag's"-table on them, but the controller still sends data also when according data is changing. What could be wrong in my project?
- Sun May 26, 2013 12:58 am
- Forum: Scripting
- Topic: Adding radiobutton with a button
- Replies: 4
- Views: 11738
Re: Adding radiobutton with a button
Hi everybody! I am trying to use this example for runtime objects creating too. But on line: this.Controls.Add(...); I have gotten an error: 'Neo.ApplicationFramework.Generated.EngineState' does not contain a definition for 'Controls' and no extension method 'Controls' accepting a first argument of ...
- Fri May 17, 2013 5:57 am
- Forum: Controller Communication
- Topic: How to send information via J1939?
- Replies: 13
- Views: 43118
Re: How to send information via J1939?
It's a win! How little a man need to be happy
For proper operation on Win7 iX Developer must be run in administrator mode.
Thank you very much for your help. Further should be easier
For proper operation on Win7 iX Developer must be run in administrator mode.
Thank you very much for your help. Further should be easier
- Fri May 17, 2013 12:47 am
- Forum: Controller Communication
- Topic: How to send information via J1939?
- Replies: 13
- Views: 43118
Re: How to send information via J1939?
Thanks for the tips, but unfortunately rebuilding did not help. Strange, it seems impossible to override driver settings. Even reinstall it on the new version fails. During the updating version 5.00.29 written. But in controller settings (even after rebooting) 5.00.12 still. Also I wanted to ask abo...