Just saw this post and....wanted to say thanks.....I always was looking for the solution for the "scaling" problem.
J
Search found 13 matches
- Sat Sep 06, 2014 8:47 am
- Forum: Application Development
- Topic: Edit Gain and Offset dynamically
- Replies: 3
- Views: 10048
- Fri Sep 05, 2014 8:40 pm
- Forum: Controller Communication
- Topic: Beckhoff ADS comm problem
- Replies: 1
- Views: 10429
Re: Beckhoff ADS comm problem
Hello, Do you still have problems with the Beckhoff ADS connection. If yes post the controller settings in the forum and I maybe be able to help. We do use this and similar PLC CX-5xxx, cx-9xxx and the communication works great. You need not only set the HMI parameters in the iX developer but you ha...
- Thu Sep 04, 2014 3:12 pm
- Forum: Application Development
- Topic: BECKHOFF ADS-Symbolic Driver and Arrays
- Replies: 1
- Views: 7119
BECKHOFF ADS-Symbolic Driver and Arrays
Programming an HMI application we would like to use the Beckhoff ADS-symbolic driver via Ethernet to one of the iXT10A HMI. My colleagues and I tried to access a one-dimensional array using index variables with no success. Doing it with the "other" ADS driver worked just fine. Does any one in this f...
- Fri Nov 08, 2013 9:33 am
- Forum: Scripting
- Topic: Change of color in a Linear meter display based on bit value
- Replies: 1
- Views: 7454
Change of color in a Linear meter display based on bit value
Hello all, Another small scripting issue as an iX developer beginner. using Information designer it was really easy to change the color of the bar-graph in a Linear Meter element. Now I want to use a similar function in the iX developer and it does not work quite I want to. I created a Variable that...
- Thu Nov 07, 2013 10:06 am
- Forum: Application Development
- Topic: About Recipes size & functionality in TxA
- Replies: 6
- Views: 13612
Re: About Recipes size & functionality in TxA
HELLO, I did solve this problem adding a TAG "TagLatestRecipeName" (String <100>) Set it as always active and non-volatile in the configuration tabs. ...and then used the "SystemTagLatestLoadedRecipeName" and do the comparison. Did the evaluation on Value change for the system TAG. _________________...
- Mon Nov 04, 2013 12:26 pm
- Forum: Scripting
- Topic: External program check
- Replies: 15
- Views: 36005
Re: External program check
Is there a way to Open a "note pad" application on a T7A HMI? The reason why I am asking is that down the road I might need to edit a NC program code as Txt file in the HMI environment and using an already existing Editor would help ding so. Any Ideas? At this moment it is not a "hot topic" for me b...
- Mon Nov 04, 2013 11:31 am
- Forum: Controller Communication
- Topic: How TO: Access the "just saved" recipe name ???
- Replies: 2
- Views: 19711
How TO: Access the "just saved" recipe name ???
Hello Everyone, Another maybe really easy question. I need to display some recipe information on the screen and can find the "last Loaded recipe" value/name in a system tag. My questions is how to get the "just saved" recipe name. My problem is that when I have a recipe loaded, change some parameter...
- Mon Nov 04, 2013 11:22 am
- Forum: Controller Communication
- Topic: T7A HMI Access via FTP
- Replies: 2
- Views: 10056
Re: T7A HMI Access via FTP
Thanks
- Mon Oct 28, 2013 3:38 pm
- Forum: Controller Communication
- Topic: T7A HMI Access via FTP
- Replies: 2
- Views: 10056
T7A HMI Access via FTP
Hello everyone. Relatively new to iX developer 2.0 but fairly familiar with the Information Designer (was using it for the last 3 years) I am trying to access the WinCE file structure on the HMI via FTP to secure the Recipe database or exported to file recipe "csv" format. It was really easy with th...
- Wed Oct 23, 2013 7:59 am
- Forum: Scripting
- Topic: Changing Text color based on instance id number
- Replies: 6
- Views: 21477
Re: Changing Text color based on instance id number
Edmund,
Thanks a lot
J
Thanks a lot
J