Search found 14 matches

by cybermen
Mon Oct 14, 2013 2:43 am
Forum: Controller Communication
Topic: Three video - three different end results
Replies: 3
Views: 10776

Re: Three video - three different end results

I am sorry but in this case iX Developer is used as an HMI (clip 2&3).

Regards,
Ilgonis
by cybermen
Thu Oct 10, 2013 3:38 am
Forum: Controller Communication
Topic: Three video - three different end results
Replies: 3
Views: 10776

Three video - three different end results

Hi All, In the first clip we will see that logic works fine when we use local simulation. In the second clip we will see that logic does not work when we use iX runtime. In the third clip we will see same as in second but logic works fine when tags %M904 and %M906 will be changed to %G904 and %G906 ...
by cybermen
Wed Oct 02, 2013 10:24 am
Forum: Hardware
Topic: iX Runtime 4000 tags licence migration problems
Replies: 3
Views: 23636

Re: iX Runtime 4000 tags licence migration problems

Yes, overall I have 3 devices called EPC C2D.
In the screen shot of Task Manager in one of devices we see that S/N of Box is 05192

Regards,
Ilgonis
by cybermen
Sun Sep 29, 2013 4:30 am
Forum: Application Development
Topic: Context menu in Alarm Viewer
Replies: 6
Views: 13901

Re: Context menu in Alarm Viewer

Only one question: how to make button 1:1 as in Alarm Viewer. In picture attached below: Button1 made from Buttons selection (simply, but impossible to repeat as in Alarm viewer), Button2 (1:1 as in Alarm Viewer) made from combination of rectangle & text (all ok, but button is complicated). ScreenSh...
by cybermen
Sun Sep 29, 2013 4:28 am
Forum: Application Development
Topic: Context menu in Alarm Viewer
Replies: 6
Views: 13901

Re: Context menu in Alarm Viewer

Ok, Here is simple way to solve problem: 1) create tag to clear alarms (in Alarm Server Settings tab); ScreenShot013_1.png 2) uncheck from respective boxes (in Alarm Wiewer General tab); ScreenShot014_1.png 3) create button called 'Clear"; 4) set security for this button in Tag/Security; ScreenShot0...
by cybermen
Sun Sep 29, 2013 2:54 am
Forum: Controller Communication
Topic: GE controllers Tag (variable) problems
Replies: 3
Views: 15607

Re: GE controllers Tag (variable) problems

Hi Mark,
Tell me please, who is the driver developer: Beijer or GE?
Regards,
Ilgonis
by cybermen
Sat Sep 28, 2013 9:10 am
Forum: Application Development
Topic: Context menu in Alarm Viewer
Replies: 6
Views: 13901

Re: Context menu in Alarm Viewer

Here is my version of security groups on buttons in the Alarm Viewer. Of course it is stupid and probably wrong way, but if Beijer Electronics support does not offer a better solution... I recorded this in a video and can be viewed with Webex tool (freely downloadable from the internet). Below i att...
by cybermen
Sat Sep 28, 2013 4:16 am
Forum: Application Development
Topic: Problems with text overlay
Replies: 2
Views: 6913

Re: Problems with text overlay

Thank You for support,
There are no overlaped text in my pic, only text box overlay on to a buttons.
It is needed when many small objects on screen and selected font too small for visibility.
Regards,
Ilgonis
by cybermen
Fri Sep 27, 2013 1:41 pm
Forum: Application Development
Topic: Context menu in Alarm Viewer
Replies: 6
Views: 13901

Re: Context menu in Alarm Viewer

Hi Mark,
Thanks for the answer!
In this case, maybe there is a way to assign Security Group Restrictions for "Clear" button?
by cybermen
Fri Sep 27, 2013 8:44 am
Forum: Application Development
Topic: Problems with text overlay
Replies: 2
Views: 6913

Problems with text overlay

Hi!
Text that overlays buttons (see attached pic.), partly affects button actions functionality.
How to solve this problem?
Regards,
Ilgonis